Doric 450-TH Thermometer 4600
     

 

Doric 450-TH Thermistor Thermometer

Specifications     Pricing

 

Connects Directly to 400 Series Probes (Except Dsposable)
 

Doric 450-TH ThermometerThe Doric 450 Series digital thermometers are among the most accurate, reliable, and convenient handheld instruments ever developed. Using a unique, patented noise reduction circuit, the Series 450 achieves the high repeatability and accuracy of many line-powered bench top units in a handheld instrument.
 

A custom-designed dual integrated circuit set gives you a single instrument with wider temperature ranges, higher resolutions, and longer performance than most other handheld thermometers. Data hold freezes the displayed reading for easy viewing away from difficult measurement locations.
 

Battery life is unsurpassed, with a single 9V battery providing more than 1200 hours of use. An externally available zero pot, conveniently located at the back of the instrument, lets you match ice point calibrations to specific probes for even greater system accuracy.

 

The 450-TH is compatible with YSI 2252Ω B curve thermistors.  The input is a standard 1/4" phone plug.

 

The 450 is also available in Thermocouple, RTD, and Thermistor configurations. Please specify when ordering.
 


YSI 4600 Precision Thermometer
Specifications    Pricing

Connects Directly to 400 Series Probes (Except Dsposable)YSI 4600 Thermometer

The handheld YSI 4600 Series Precision Thermometers takes metrology-level temperature measurement to the laboratory, the manufacturing floor and the field...at an affordable price.  The YSI 4600 offers high-precision and the convenience of a wide selection of off-the-shelf YSI 400 Precision Series Temperature Probes.  Three versions are available.

All Versions Include These FeaturesRecorder 4600 Software

  • Resolution to 0.01 on display;  0.001C on Serial Output                             

  • RS232 port (Optional Software Available)

  • Traceability to National Institute of Standards and Technology (NIST)

  • F or C readout

  • Hold

  • Min/max

  • delta T

  • Store

  • Battery Life Approx 20 Hrs.

YSI 4600-- Flexibility and Precision
The YSI 4600 is a precision thermometer for use with Standard YSI 400 Series Probes over the wide range of -40 to +150C.   The system accuracy is 0.115C with over 20 styles of YSI 400 Series Temperature Probes, including stainless steel tubular, air/gas, vinyl-tipped and catheter probes.

YSI 4610 High Accuracy

Higher Accuracy with Custom Interchangeable Probes.  The YSI 4610 offers extremely high system accuracy when you use it with YSI custom interchangeable probes that are tested and calibrated just for this thermometer. System accuracy is 0.05C from 20 to 50C with two special probes: a catheter probe and a vinyl tip general-purpose probe. The temperature range is 0 to 70C.

YSI 4600S-- Transfer Standard
The YSI 4600S offers metrology-level accuracy over a range you define. Your unit is calibrated at up to four points along with a YSI Configure-to-Order Probe (using YSI 46000 Super-Stable Glass Thermistors) appropriate for your application. This provides you the highest accuracy, 0.025C from 0 to 50C, and NIST traceability. Useful applications include:


4600
Communications Parameters:
Serial Communications Protocol      Serial Communications Setup


 

YSI 4000  Dual Channel Precision Thermometer


We are sorry, but the YSI 4000 series has been discontinued by YSI.  Please use the Doric 450-TH, YSI 4600 Series or Hart Scientific 1520 Series.   For a multi-channel replacement see the Hart Scientific 1529.  If you need the old specifications, we have located them here.  YSI 4000 Specifications.
 


Thermistor Transmitter for 400 series Probes PR-5343-2252BW
Specifications

  • Designed 400 Series Probes and Thermistors.

  • Provides Linearization for 2252 ohm 400 Series Thermistors and Probes

  • 4 - 20 mA Linearized Output (-30 to +70C)

  • Output Linear with Temperature

  • Custom Curves Available

  • Head or DIN Rail Mounted (with optional adapter)

YSI 4000  Dual Channel Precision Thermometer


We are sorry, but the YSI 4000 series has been discontinued by YSI.  Please use the Doric 450-TH, YSI 4600 Series or Hart Scientific 1520 Series.   For a multi-channel replacement see the Hart Scientific 1529.  If you need the old specifications, we have located them here.  YSI 4000 Specifications.
 


 

Hart Scientific 1521 and 1522 Ultra Precision Handheld Thermometers

Specifications   Pricing

 

Requires Connector Change for 400 Series Probes
    

Hart Handheld ThermometerThe Hart Scientific Series of Thermistor Thermometers provide laboratory accuracy in a convenient handheld format.  With the Super-Thermometer, Black Stack, and Tweener thermometers, Hart established itself as the clear product leader for thermometer readouts. Our pattern of offering more power and more versatility for less money is indisputable.  Hart offers the two most powerful handheld thermometers in the world.

The Models 1521 and 1522 are the first standards thermometers to fit into a battery-powered handheld package. Theyre as accurate as 0.005C!  Fitting easily into your hand and weighing only 1 pound (0.4 kg), these thermometers can go anywhere.  And when they get there, you can have total confidence in the accuracy of your measurements.  The 1522 adds the power of a full data logger, with memory to hold 10,000 readings.

Ultra-stable thermistors offer excellent stability and even greater accuracies over a more narrow rangetypically from about 10C to 110C. At temperatures below 50C, these Handheld Thermometers read thermistors to 0.005C. Accuracy at 100C is 0.02C.  While a small number of handheld thermometers on the market offer 0.01 resolution, they fail to provide the accuracy necessary for the last digit to be meaningful. Harts Handheld Thermometers let you select resolution from 0.1 to 0.001 and offer the accuracy to support even 0.001 resolution. 

Probes attach to the 1521 and 1522 using Harts own INFO-CON connector. The INFO-CON (partially based on U.S. Patent 5,857,777) allows you to change the probes you use without requiring you to reprogram your readout. A memory chip in the INFO-CON stores all the critical information about your probe, including its serial number, recall date, and calibration constants. 


 

Doric 600 Series Thermistor Thermometer

Specifications     Pricing


Doric 600 Series
Requires Connector Change for 400 Series Probes

 

The Doric 600 Series digital thermometers are among the most accurate, reliable, and convenient benchtop  instruments ever developed. Using a unique, patented noise reduction circuit, the Series 600 achieves the high repeatability and accuracy you would expect.
 

A custom-designed dual integrated circuit set gives you a single instrument with wider temperature ranges, higher resolutions, and longer performance than most other handheld thermometers.

 

Also available in multi-channel configurations, and with alarms.
 

Thermistor Range Table

Sensor Type Order Code Range/Display Accuracy () Resolution
Thermistor Series
YSI 400, 225 @25C
2-wire
-6 -42 to +221F
-41 to +105C
231 to 458 K
0.4F
0.2C
0.2 K
0.02F
0.01C
0.01 K
Thermistor Series
YSI 700
3-wire
-6 +31 to +213F
0 to +100C
272 to 373 K
0.4F
0.2C
0.2 K
0.01F
0.01F
0.01 K


The 600 is also available in thermocouple, RTD, and thermistor configurations. Please specify when ordering.
 


Hart Scientific 1504 
Resolution to 0.0001

Specifications   Pricing

 

Requires Connector Change for 400 Series Probes

Hart 1504 Ultra Precision Thermometer

One of Harts best-selling products is the Tweener thermometer, and theres a reason. No other company, not one, has a thermometer that comes close to the performance and features of the Tweener for anywhere near its price.

The Model 1504 features accuracy up to  0.003C with a resolution of 0.0001C.  It also has an optional battery pack for completely portable operation.

Each Tweener is programmable to match any probes constants for maximum linearity and accuracy. All probe constants and coefficients are programmed through simple, front-panel keystrokes. Temperature is displayed in C, F, K, or resistance in ohms.

Each thermometer comes complete with an RS-232 interface for automation of temperature data collection, calibrations, or process control functions. An IEEE-488 interface is available as an option.

The 1504 is calibrated digitally using the front-panel buttons. You never have to open the box to calibrate it. This calibration protocol further reduces the cost.  It goes where you go and works the way you want it to.

Software

With our Model 9934 LogWare,  Tweener models may be used for real-time data acquisition. Collect data and analyze it graphically or statistically. Additionally, Tweeners may be used as reference thermometers with our MET/TEMP II software. 


Hart Scientific 1529

4 Channel Thermometer
Specifications  Pricing

 

Requires Connector Change for 400 Series Probes

 

1529Four channels for PRTs, thermistors, and thermocouples  Displays eight user-selected data fields from any channel.  Logs up to 8,000 readings with date and time stamps.  Battery provides eight hours of continuous operation. 

Hart’s Model 1529 Chub-E4 Thermometer gives you four channels, three major sensor types, lab-quality accuracy, and a ton of great features, all at a price you’ll love. 

Inputs 

The Chub-E4 has four inputs for reading four different sensors simultaneously, and we’ll configure those inputs in any of three different ways according to your preference. Choose four channels of thermocouple inputs, four channels of PRT/thermistor inputs, or two channels of each. With this thermometer, reading thermocouples, PRTs, and thermistors accurately from the same device is no problem. 

 

Thermistor readings are converted using the Steinhart-Hart polynomial or standard YSI-400 curve and are as accurate as ±0.0025°C at 25°C with resolution of 0.0001° 

 

PRTs and thermistors connect easily to the 1529 using Hart’s patented mini DWF connectors, which accept bare wire, spade lug, or mini banana plug terminations. Thermocouples connect using standard or miniature terminations. Measurements are taken each second and can be taken simultaneously or sequentially. A special high-speed mode allows measurements on one channel to be taken at the rate of 10 per second. 

 

Display

If you think three sensor types and four inputs sounds versatile, wait until you see the display panel on the Chub-E4. Displaying measurements in °C, °F, K, ohms, or millivolts and choosing temperature resolution from 0.01 to 0.0001 are just the beginning. 

You can also select any eight items from our long list of displayable data fields to view on-screen. Choose statistical functions such as averages, standard deviations, and spreads; choose probe information such as probe type and serial number; choose T1-T2 functions using inputs from any two channels; or choose utility functions such as the date, time, and battery power level. You can even save up to 10 screen configurations for easy recall. 

 

The push of a single front-panel button also brings up a simple menu system to easily guide you through all the internal setup and memory options of the 1529. Probe coefficients, sample intervals, communication settings, password settings, and a host of other functions are all easily accessible. 

 

Communications 

The memory and communications capabilities of the Chub-E4 make it perfect for benchtop thermometry, on-site measurements, lab calibration work, and remote data logging. Optional software packages from Hart make this one of the most powerful thermometers on the market. 

With battery power and memory to store up to 8,000 measurements (including date and time stamps) at user-selected intervals, the 1529 has plenty of data logging capability. Store 100 individual measurements or any number of automatic log sessions (up to 8,000 readings), each tagged with an identifying session label. Fourteen different logging intervals may be selected, from 0.1 second to 60 minutes.  

 

With Hart’s 9935 LogWare II, data may be quickly downloaded to your PC for complete graphical and statistical analysis. Separate log sessions may even be automatically downloaded to separate files based on session labels. With this software, the 1529 can even be used for real-time data logging. Log four channels at once directly to your PC with virtually no limit to the number of data points you take. You can analyze data, set alarm events, and even set delayed start and stop times. 

 

With MET/TEMP II software, the Chub-E4 may be integrated into a completely automated calibration system. Use one input for your reference thermometer and calibrate up to three other thermometers automatically. An RS-232 port is standard on every unit. An IEEE-488 port is optional. 


 

Thermistor Transmitter for 400 series Probes
PR-5343-2252BW 
$  249.00
Pricing    Specifications

  • Designed for 400 Series Thermistors.

  • Provides Linearization for 2252 ohm 400 Series Thermistors and Probes

  • Output Linear with Temperature

  • Custom Curves Available

  • Head or DIN Rail Mounted (with optional adapter)

  • 4 - 20 mA linear output (-30 to +70C)

 


Thermistor Input Module for Data Acquisition Systems - M7005
Pricing

8-channel Thermistor Input and 6-channel Alarm Output Module -  DComm protocol
  • Communication Interface: DComm Protocol RS-485
  • Input Type : Thermistor
  • Input Channels: 8
  • Thermistor Types : Precon ST-A3, Fenwal U, YSI L100, YSI L300, YSI L1000,
        YSI B2252, YSI B3000, YSI B5000, YSI B6000, YSI B10000, YSI H10000,
         YSI H30000, User-defined
  • Resolution : 16-bits
  • Accuracy : +/-0.1%
  • Sampling Rate : 8 samples/second (Total)
  • -3dB Bandwidth : 5.24Hz
  • Common Mode Rejection : Typical 86dB
  • Voltage Input Impedance : >1M Ohms
  • Individual Channel Configurable
  • Wire Opening Detection
  • Alarm Output Type : Open collector
  • Alarm Output Channels: 6 (NPN, Sink)
  • Open collector to 30V, 100mA max. load (per channel)
  • Isolation Voltage : 3000Vdc

  • Additional Information:     Pricing       Thermistor Probes      Thermistors      400 Series & Medical Probes      Custom Probes

    Thermistor Thermometer, Thermistor Readout, YSI thermometer, Doric, Hart Scientific, thermistor input module, precision thermometer, Doric Thermometer, Medical Temperature, Life Science Temperature, YSI Temperature

    I would like you to
    Name
    Company
    Address
    City, State, Zip
    Country
    Phone Number
    Fax Number
    E-Mail
    Comments

     
    Home Page      Site Index      Contact Us      Applications Notes and Tables      Products      Manuals      On Line Order

    Note:  Prices shown are for reference only, and may change without notice.  Contact Advanced Industrial Systems, Inc. for firm price quotations.

    Advanced Industrial Systems, Inc.
    1-800-532-2477         Fax:  1-502-228-0127       Sales@AdvIndSys.com

    American Express

    Visa

    Mastercard

    Discover

    Copyright 1997 - 2013 Advanced Industrial Systems, Inc. All rights reserved.
    Last modified: Wednesday October 23, 2013.